400 - Fluorescent Slim Light Specification
| SERIES |
WATT |
LAMP QTY |
HUB |
ORDER # |
VOLTAGE |
| 390420 (2 lamp) |
32W T8 |
2 |
1/2" NPT |
390420 3613 |
120-277 Volts 50/60 Hz |
| |
|
2 |
1/2" NPT |
390420347 3276 |
347 Volts 60 Hz |
| |
32W T8HLO |
2 |
1/2" NPT |
390420120 1744 |
120-277 Volts 50/60 Hz |
| |
|
2 |
1/2" NPT |
390420277 1766 |
347 Volts 60 Hz |
| |
54W T5HO |
2 |
1/2" NPT |
390420 3265 |
120-277 Volts 50/60 Hz |
| |
|
2 |
1/2" NPT |
390420 5420 |
347 Volts 60 Hz |
| |
| 390440 (4 lamp) |
32W T8 |
4 |
1/2" NPT |
390440 3546 |
120-277 Volts 50/60 Hz |
| |
|
4 |
1/2" NPT |
390440347 3125 |
347 Volts 60 Hz |
| |
32W T8HLO |
4 |
1/2" NPT |
390440120 1744 |
120 Volts 50/60 Hz |
| |
|
4 |
1/2" NPT |
390440277 1766 |
277 Volts 50/60 Hz |
| |
54W T5HO |
4 |
1/2" NPT |
390440 4843 |
120-277 Volts 50/60 Hz |
| |
|
4 |
1/2" NPT |
390440347 3125 |
347 Volts 60 Hz |
. |
| 390460 (6 lamp) |
32W T8 |
6 |
1/2" NPT |
390460 3546 |
120-277 Volts 50/60 Hz |
| |
|
6 |
1/2" NPT |
390460347 3125 |
347 Volts 60 Hz |
| |
32W T8HLO |
6 |
1/2" NPT |
390460120 3124 |
120 Volts 50/60 Hz |
| |
|
6 |
1/2" NPT |
390460277 3277 |
277 Volts 50/60 Hz |
| |
54W T5HO |
6 |
1/2" NPT |
390460 3265 |
120-277 Volts 50/60 Hz |
| |
|
6 |
1/2" NPT |
390460 5420 |
347-480 Volts 50/60HZ |
 |
Note: Light Fixture's glass
frame extends 3/8" into
booth when mounted in
booth panel. |

SPECS
|
Type
|
Model
|
"A"
|
"B"
|
"C"
|
"D"
|
|
4 Ft. 2 Lamp Inside Access
|
390420
|
9-1/2"
|
13"
|
50"
|
51-7/8"
|
|
4 Ft. 4 Lamp Inside Access
|
390440
|
14-1/2"
|
18"
|
50"
|
51-7/8"
|
|
4 Ft. 6 Lamp Inside Access
|
390460
|
19-1/2"
|
23"
|
50"
|
51-7/8"
|
|

|
Hole Detail Dimensions
|
| TYPE |
"E"
|
"F"
|
| 2 Lamp Fixture |
10-3/4"
|
7"
|
| 4 Lamp Fixture |
15-3/4"
|
12"
|
| 6 Lamp Fixture |
20-3/4"
|
17"
|
|
| Options |
Part Number |
| 10ft Wire Lead Assy |
3405 |
| 8ft Wire Lead Assy |
3646 |
|
IMPORTANT: Normally open magnetic switches are intended to be used to trigger a relay which disables the paint system. Because of the small capacity of the switch, a solid state relay is recommended. It may be desired by others to utilize a seperate power supply to segregate the relay from lighting power supply. The magnetic switch is reated for 10 watts (resistive) at a maximum of 300 VAC. The magnetic switch is NOT designed to directly control light operations.
CAUTION: Overloading the switch circuits will cause failure. LDPI® recommends having a certified electrician/engineer review circuit loads to insure that overloading of switch does not occur. |
|